02.06.2021
How to Achieve Surface Quality Levels (Q1-Q4) with a Banjo, Roller and Skimming Spatula?
In this article we explain how to achieve the four levels of surface finishing – Q1, Q2, Q3 and Q4 according to Eurogypsum’s classification.
Here are the steps we followed:
Level Q1:
First, we mix on low speed the ready-to-use mix FUGA&FINISH adding in portions water to dilute to the desired semi-liquid consistency. This way we ease the tape application with banjo.
We load the paper roll in the banjo, pull out the end and set it in position, then we fill up the banjo with the plaster mixture.
We set the mixture layer thickness to maximum and we proceed to applying the tape.
For vertical joints, begin applying the tape from up to down, supporting the top end of the tape with one hand, while pulling the banjo downwards.
The so applied tape and mixture needs to be smoothed with trowel and taping knife to achieve good contact with the wallboards on both sides of the joint.
Level Q2:
To be able to continue with level Q2 – aligning the joint area with continuous transition to the board surface with ready-mix FUGA & FINISH, the absolutely necessary requirement is the first layer, level Q1 to be completely dried.
One of the most important steps in prepping a ready-to-use compound is to pre-mix it with a mechanical stirrer at a low speed after opening the package. When applied with roller, it is necessary the compound to be diluted with approximately 200 ml of water per 20 kg of product, water is added gradually to achieve the desired liquid consistency suitable for this method.
Using a roller, apply a thin layer of the mixture along the entire length of the joint, then moving vertically the skimming spatula smooth the surface. The total width of the mixture strip on both sides of the joint should be approx. 400 mm along its entire length. This is sufficient to ensure a continuous gradual transition from the joint to the wallboard surface.
Level Q3:
It is mandatory that the previous layer - level Q2 is finished and dry and all joints are smoothed and filled so that they are not see through.
One of the most important steps in using a ready to use compound is to pre-mix it with a mechanical stirrer at a low speed after opening the package. When using a roller, the compound should be diluted with 200 ml of water per 20 kg of product, water is added gradually to achieve the desired liquid consistency suitable for application.
Using a plaster roller, apply a thin layer of the mixture over the entire surface of the wall. Then with the help of a skimming spatula smooth the surface.
If required, the surface could be smoothed with fine sandpaper, but only after complete drying of the plaster.
Level Q4:
It is mandatory that the previous layer - level Q2 is finished and dry and all joints are smoothed and filled so that they are not see through.
The first and very important step is to pre-mix the ready to use compound FUGA & FINISH with a mechanical stirrer at a low speed, after opening the package. When using a roller, the compound should be diluted with 200 ml of water per 20 kg of product, water is added gradually to achieve the desired liquid consistency suitable for application.
Using a plaster roller, apply a thin layer (no more than 3 mm) of the mixture over the entire surface of the wall. Then smooth the surface using a skimming spatula.
After the wall is completely dry, all imperfections must be smoothed with fine sandpaper. Using LED floodlight will help you spot them easily.
*Eurogypsum – European federation of the gypsum product manufacturing industry. Developed and established, the 4 levels of quality finish classification for plasterboard cladding aims to provide clear definitions thus helping to reduce subjective judging of the end result.
Level Q1 is a basic requirement for joints filling between the gypsum wallboards (including the visible parts of the screws) and is considered sufficient for surfaces with following decorative thin-layered coatings. The surface achieved with level Q1 is suitable for ceramic wall tiles and coarse structured wall coating with thickness of at least 2mm, etc.
Level Q2 fulfills the basic requirements for finishing of walls and ceilings. This quality level’s basic objective is to align the joint area and to ensure a continuous translation to the plasterboard surface.
Level Q3 responds to higher demands of quality of the finished surface.
Level Q4 responds to the highest demands of quality of the finished surface.